Microprocessor-controlled Portable X-ray NTD Equipment
- Courier
- In detail
I. General
The frequency-converted and gas-insulated portable X-ray NDT equipment with ZY-2000 controller, is one of upgrading generation of the products by the Mitech Co.,Ltd. Besides of its advantages of small size, light weight, easy to use, simple operation and self-troubleshooting, this new type of controller has the excellent performance of strongly interference-free capability, good working stability and operating reliability. With the popularization and spreading application of this new type NDT X-ray equipment all over the country, it has been recognized and welcomed by the customers from different industries
This portable X-ray NDT equipment can be used in the fields of ship-building, mechanical manufacturing, aviation, railroad, pressure vessel, boiler, petroleum, chemical and national defense, performing the non-destructive testing, especially at the construction site or high above the ground applications.
二、Technical Data
Model
Parameters Item |
XXQ-1005
XXH-1005 |
XXQ-1605
XXH-1605 XXG-1605 |
XXQ-2005
XXG-2005 XXH-2005 XXHA-2005 |
XXQ-2505
XXG-2505 XXH-2505 XXHA-2505 |
XXQ-3005
XXG-3005 XXH-3005 XXHA-3005 |
XXQ-3505
XXG-3505 XXH-3505 XXHA-3505 |
|||
Power supply | AC220V+-10%50Hz | ||||||||
Power (kW) | >1.0 | >1.5 | >2.5 | >2.5 | >3.0 | >3.5 | |||
Tube voltage (kVp) | 60-160 | 80-200 | 130-250 | 150-300 | 200-350 | ||||
Max. Tube
current (mA) |
5 | 5 | 5 | 5 | 5 | 5 | |||
Focal Spot Size
(mm x mm) |
Q.G | 1.0*1.0 | 1.5*1.5 | 1.5*1.5 | 2.0*2.0 | 2.5*2.5 | 2.5*2.5 | ||
H | 1.0*1.5 | 1.0*2.0 | 1.0*2.0 | 1.0*2.4 | 1.0*2.5 | 1.0*2.5 | |||
HA | 1.0*2.5 | 1.0*3.5 | 1.0*3.5 | 1.0*5.0 | 1.0*6.0 | 1.0*6.0 | |||
Weight
kg |
Tube | Q | 11 | 15 | 20 | 35 | 44 | 44 | |
G | 14 | 20 | 32 | 37 | 37 | ||||
H.HA | 11 | 15 | 20 | 35 | 44 | 44 | |||
Controller | 11 | ||||||||
Radiation angle of
X-ray |
Q | 40º | |||||||
G | 360ºX25º | ||||||||
H.HA | 360ºX30º | ||||||||
Max. penetration
A3 steel(mm) |
Q. G | 8 | 20 | 29 | 39 | 49 | 59 | ||
H | 6 | 18 | 26 | 36 | 46 | 56 | |||
HA | 15 | 24 | 34 | 40 | 50 | ||||
Insulation | SF6gas | ||||||||
Environmental temperature | -25℃-+40℃ | ||||||||
Relative Humidity | No more than 85% | ||||||||
Working conditions of X-rayphotography | 1. Focus to Film: 600mm
2. Exposure time: 5 min. 3. Film: Tian Jing, Model III, intensified by double lead foil. 4. Treatment in the darkroom: Temp. 20 +/-2ºC, 5 min. blackness ≥ 1.5 |
||||||||
Safe working pressure
Of gas |
0.35 ~ 0.50 Mpa
(Operation will be prohibited in the case less than 0.35 Mpa) |