Quality Test Analyzer Intelligent Calibration Equipment
In stock
Reconfirm the price with seller
- Courier
- In detail
Products of other enterprises
Description
Main Specification | |
1. AC analogue output | |
1.1 AC voltage output | |
Range | 100V, 220V |
Adjustment range | (0— 120V)%RG, RG is the range, the below is same. |
Adjustment fineness | 0.01%RG; Accuracy: 0.05%RG; Stability: 0.01% / 2min; |
Distortion | < 0.1%( non-capacitive load ); output load: 25VA for every phase |
1.2 AC current output | |
Range | 0.2A, 1A, 5A, 10A |
Adjustment range | (0— 120V)%RG, RG is the range, the below is same. |
Adjustment fineness | 0.01%RG; Accuracy: 0.05%RG; Stability: 0.01% / 2min; |
Distortion | < 0.1%( non-capacitive load ); output load: 25VA for every phase |
1.3 Fundamental Power output | Accuracy: 0.05%RG; Stability: 0.01% / 2min |
1.4 Phase output | Adjustment range: 0° ~ 359.99° ; Resolution: 0.001° ; Accuracy: 0.05° |
1.5 Power factor | Adjustment range: -1~0~+1; Resolution: 0.0001; Accuracy: 0.05% |
1.6 Frequency | Adjustment range: 45Hz~65Hz; Resolution: 0.001Hz; Accuracy: 0.002Hz; |
1.7 Symmetry of three-phase voltage, current and phase |
Symmetry of voltage and current < 0.02%; Symmetry of phase < 0.05° |
1.8 Voltage and current harmonic setting: |
Number of Harmonic: 2~63 times; harmonic content: 0~40%; harmonic phase: 0° ~359.99° ; harmonic voltage: Uh≥ 1%UN, accuracy: 1% Uh Uh < 1%UN, accuracy: 1% UN Harmonic current: Ih≥ 3%IN, accuracy: 1%Ih Ih < 3%IN, accuracy: 0.05IN (h is harmonic times, Uh is harmonic voltage, UN is nominal voltage, Ih is harmonic current, IN is nominal current) |
1.9 Output flicker value pst | Accuracy: 1% |
1.10 Harmonic active power | Ph ≥ 150W, accuracy: 0.2%PN Ph < 150W, accuracy: 0.5W |
2. Remote communication interface |
RS-232, RS-485 |
3. Working condition | Working temperature: 10º C~ 30º C, relative humidity ≤ 85%, storage condition: - 30º C~ 60º C |
4. Working power | AC 220V ± 15% |
5. Volume | 450 × 440 × 156 mm |
6. Weight | 12kg |
Contact the seller